Pumping stations Muli-Max mono/duo – load class: D 400 (2023)

Product information

  • Application areas
    • Single and multiple family houses
    • Office buildings
    • Industrial buildings
    • Pressure Drainage
  • Single or double pump station for below ground installation from polyethylene
  • Tested according to EN 12050
  • With automatic above water coupling
    • Suitable for submersible pumps from ACO
  • Pressure connection from PE-HD DN 50 (OD 63 mm), with ball valve and compression fitting 63 x 63 mm OD
  • Installation height: 2,200-3,000mm
  • Connecting height (from top of tank to center of pressure connection): 1,150 – 1,950 mm mm
  • Two inlets OD 160 mm, connecting height top of cover until center of pipe: 1,425 – 2,225 mm, one sealing ring in scope of delivery
  • Two inlets OD 110 mm, connecting h height top of cover until center of pipe height: 1,425 mm – 2,225 mm
  • Two connections OD 110 mm for cable pipe and ventilation, connecting height top of cover until center of pipe height: 70 – 1,570 mm
  • Connection with pipe sleeve R ½” for rinsing connection / vacuum interruption (accessories)
  • Manhole cover (optionally locked)
    • Load class: D400
    • Opening: 600 mm according to EN 124
    • Without ventilation
    • With lifting tool
  • With load distribution plate: OD 1550 mm/ID 625 mm, height 200 mm from reinforced concrete
  • With raising tube
    • Height: 1,300 mm
    • Height-adjustable, inclusive sealing ring
  • Suitable submerged pumps mono/duo
    • Submerged pumps
  • Order information
  • Accessories
TypeDescriptionHeightUsable volumeWeightItem
number
DownloadsRemember
To
[mm][l][kg]
Mono
  • Cover: placed loosely
22502709850178.13.86
Mono
  • Cover: screwed shut odour-proof
225027010620178.13.87
Duo
  • Cover: placed loosely
22502709980178.13.88
Duo
  • Cover: screwed shut odour-proof
225027010760178.13.89
TypeDescriptionHeightUsable volumeWeightItem
number
To
Pumping stations Muli-Max mono/duo – load class: D 400 (1)Mono
  • Cover: placed loosely
2250 mm270 l985 kg0178.13.86
Pumping stations Muli-Max mono/duo – load class: D 400 (2)Mono
  • Cover: screwed shut odour-proof
2250 mm270 l1062 kg0178.13.87
Pumping stations Muli-Max mono/duo – load class: D 400 (3)Duo
  • Cover: placed loosely
2250 mm270 l998 kg0178.13.88
Pumping stations Muli-Max mono/duo – load class: D 400 (4)Duo
  • Cover: screwed shut odour-proof
2250 mm270 l1076 kg0178.13.89
Submerged pump

Switching device, ACO Multi Control Mono

Suitable for
  • Muli-Max
    • Mono-plant
Description
  • For pumps up to 5,5 kW
  • Plug and use with 1.5 m mains cable
  • EEC 16-plug with phase inverter
  • 20 m pneumatic control line 10 x 1.5 mm
  • Dynamic pressure bell
  • Cable duct
  • Operating voltage: 400 V
  • Frequency: 50/60 Hz
  • Control voltage: 230 V/AC
  • Current consumption when idling: max 8 VA
  • Temperature range: -20 to +60 °C
  • IP 54 protection
  • Weight: 4 kg

Downloads

Add to wallet

Item no.
0178.63.79

Switching device, ACO Multi Control Mono Professional

Suitable for
  • Muli-Max
    • Mono-plant
Description
  • For pumps up to 5,5 kW
  • Plug and use with 1.5 m mains cable
  • EEC 16-plug with phase inverter
  • 20 m pneumatic control line 10 x 1.5 mm
  • Dynamic pressure bell
  • Cable duct
  • Operating voltage: 400 V
  • Frequency: 50/60 Hz
  • Control voltage: 230 V/AC
  • Current consumption when idling: max 8 VA
  • Temperature range: -20 to +60 °C
  • IP 54 protection
  • With Modbus RTU - functionality for connection to the building management system
  • Weight: 4 kg

Downloads

Add to wallet

Item no.
0178.64.38

Switching device, ACO Multi Control Duo Professional incl. Dynamic pressure bell

Suitable for
  • Muli-Max
    • Duo-plants
  • Powerlift–P
  • Muli-Flex
Description
  • For pumps up to 5,5 kW
  • Plug and use with 1.5 m mains cable
  • EEC 16-plug with phase inverter
  • 20 m pneumatic control line 10 x 1.5 mm
  • Dynamic pressure bell
  • Cable duct
  • Operating voltage: 400 V
  • Frequency: 50/60 Hz
  • Control voltage: 230 V/AC
  • Current consumption when idling: max 10 VA
  • Temperature range: -20 to +60 ° C
  • IP 54 protection
  • Weight: 5.4 kg

Downloads

Add to wallet

Item no.
0178.64.39

Switching device, ACO Multi Control Duo incl. Dynamic pressure bell

Suitable for
  • Muli-Max
    • Duo-plants
  • Powerlift–P
  • Muli-Flex
Description
  • For pumps up to 5,5 kW
  • Plug and use with 1.5 m mains cable
  • EEC 16-plug with phase inverter
  • 20 m pneumatic control line 10 x 1.5 mm
  • Dynamic pressure bell
  • Cable duct
  • Operating voltage: 400 V
  • Frequency: 50/60 Hz
  • Control voltage: 230 V/AC
  • Current consumption when idling: max 10 VA
  • Temperature range: -20 to +60 ° C
  • IP 54 protection
  • For pumps up to 5,5 kW
  • Plug and use with 1.5 m mains cable
  • EEC 16-plug with phase inverter
  • 20 m pneumatic control line 10 x 1.5 mm
  • Dynamic pressure bell
  • Cable duct
  • Operating voltage: 400 V
  • Frequency: 50/60 Hz
  • Control voltage: 230 V/AC
  • Current consumption when idling: max 10 VA
  • Temperature range: -20 to +60 ° C
  • IP 54 protection
  • Weight: 5.4 kg

Downloads

Add to wallet

Item no.
0178.63.80

Switching device, ACO Multi Control Duo without Dynamic pressure bell

Suitable for
  • Muli-Max
    • Duo-plants
  • Powerlift–P
  • Muli-Flex
Description
  • For pumps up to 5,5 kW
  • Plug and use with 1.5 m mains cable
  • EEC 16-plug with phase inverter
  • 20 m pneumatic control line 10 x 1.5 mm
  • Dynamic pressure bell
  • Cable duct
  • Operating voltage: 400 V
  • Frequency: 50/60 Hz
  • Control voltage: 230 V/AC
  • Current consumption when idling: max 10 VA
  • Temperature range: -20 to +60 ° C
  • IP 54 protection
  • For pumps up to 5,5 kW
  • Plug and use with 1.5 m mains cable
  • EEC 32-plug with phase inverter
  • Without pneumatic control line and dynamic pressure bell
  • Cable duct
  • Operating voltage: 400 V
  • Frequency: 50/60 Hz
  • Control voltage: 230 V/AC
  • Current consumption when idling: max 10 VA
  • Temperature range: -20 to +60 ° C
  • IP 54 protection
  • Weight: 6.0 kg
  • Weight: 5.4 kg

Downloads

Add to wallet

Item no.
0178.63.94

Flashing light

Suitable for
  • Signalling unit with voltage-free fault reporting
  • LipuSmart-P
  • Muli-Max with signalling unit
  • LipuLift-P
Description
  • 230V
  • Power consumption: 70 mA
  • Weight: 0.5 kg

Downloads

Add to wallet

Item no.
0178.62.08

(Video) 400 AMP residential ELECTRIC SERVICE using TWO parallel 200 AMP service ENTRANCES (076)

Flashing light

Downloads

Add to wallet

Item no.
0150.76.25

Suitable for
  • For faecal and non-faecal wastewater
  • MultiControl controls as float switches
  • MultiControl controls as additional High alarm float
Description
  • Housing: PRE-ELEC PP
  • Degree of protection: IP68
  • Switch voltage: 4-40 V
  • Switch current: 1-100 mA
  • Connection cable: 10m
  • Switch inclination: 10°
  • Protection class: II 1G Ex ia IIC T6 Ga

Downloads

Add to wallet

Item no.
0159.12.45

Drill connection seal DN 110

Description
  • Weight: 0.4 kg

Downloads

Add to wallet

Item no.
0150.27.07

Drill connection seal DN 150

Description
  • Weight: 0.5 kg

Downloads

Add to wallet

Item no.
0117.03.80

Foot for buoyancy protection

Description
  • Weight: 11.5 kg

Downloads

Add to wallet

Item no.
0178.13.90

Signalling unit

Suitable for
  • Faecal matter backflow automatic stop Quatrix-K type 3F
  • All Muli wastewater lifting plants
  • Upstream tank plant mono/duo
  • Muli-Max
  • Sinkamat –K/-KD
  • Sinkamat-Z
  • Sinkamat-Z (underfloor)
    • Duo
  • LipuLift-P
Description
  • Self-charging
  • With floating contact
  • Visual and acoustic
  • Without contact transmitter
  • For mounting outside the potentially explosive atmosphere
  • Dimensions: 175 x 125 x 75 mm W x H x D
  • Protection type: IP65
  • Operating voltage: 230 V/AC 50/60 Hz
  • Ready to plug in with cable: 2 m
  • Weight: 1.4 kg

Downloads

Add to wallet

Item no.
0150.26.73

Message system with GSM module

(Video) Compulsions | Critical Role | Campaign 3, Episode 40
Suitable for
  • All grease separators
  • Grease layer thickness measuring device
  • Pre-tank plants
  • Technical processing systems
  • Quatrix-K backflow preventer type 3F
  • Sinkamat-K (underfloor) duo
  • Muli lifting units
  • Pumping stations
  • Installation sets
Description
  • Parameter via app (Android & iOs)
  • Mains-independent alarm via 12V lead-gel battery
  • Optical and acoustic alarm message
  • Freely configurable inputs
    • 6 digital inputs with LED status display
    • 1 analogue
  • 1 alarm output 12 V
  • Alarm forwarding via SMS to mobile phones
  • For mounting outside the hazardous area
  • Housing: 192 x 150(with cable gland) x 100 mm (WxHxD)
  • Protective doctor: IP54
  • Operating voltage: 230 V/AC 50/60 Hz
  • Translated with www.DeepL.com/Translator (free version)
  • Weight: 2 kg

Downloads

Add to wallet

Item no.
0150.80.14

Signal horn

Suitable for
  • Signalling unit with voltage-free fault reporting
  • LipuSmart-P
  • Muli-Max with signalling unit
  • LipuLift-P
Description
  • 230V AC
  • Power consumption: 30mA
  • Ø62x85 mm (L/B x T)
  • Protection: IP66
  • 95 dB(A)
  • Weight: 0.3 kg

Downloads

Add to wallet

Item no.
0178.61.94

Signal horn

Suitable for
  • Signalling unit
  • Signalling unit with GSM module
Description
  • Operating voltage: 12V DC
  • Power consumption: 30 mA
  • 62 x 62 x 85 mm (LxWxD)
  • Degree of protection: IP66
  • Noise level: 95 dB(A)
  • Weight: 0.2 kg

Downloads

Add to wallet

Item no.
0150.58.14

Air bubble injection

Suitable for
  • Muli-Max
  • Powerlift–P
  • Muli-Flex
Description
  • To increase operational safety (where floating surfaces are generated e.g. grease separator)
  • For pneumatic level switching
  • Mini compressor
    • Connection: 230 V
    • Plug and use
  • With T-screw-in connection
  • With backflow valve
  • Weight: 0.6 kg

Downloads

Add to wallet

Item no.
0150.25.45

Outdoor cabinet

Description
  • Dimensions: 310 x 1460 x 207 mm (H x W x D)
  • With pre-fuse C16 (16 A)
  • With 10 mm² PE-terminals for voltage compensation
  • Flashing light (knock resistant)
  • Closed using safety lock cylinder
  • Weight: 21 kg

Downloads

Add to wallet

Item no.
0178.63.84

Outdoor cabinet

Description
  • Dimensions: 310 x 1460 x 207 mm (H x W x D)
  • With pre-fuse C16 (16 A)
  • With 10 mm² PE-terminals for voltage compensation
  • Flashing light (knock resistant)
  • Closed using safety lock cylinder
  • Weight: 21.1 kg

Downloads

Add to wallet

Item no.
0178.63.85

Outdoor cabinet

Suitable for
  • Muli-Max
  • Powerlift–P
  • LipuLift-P-B/P-D
Description
  • As empty housing
  • Dimensions: 310 x 230 x 1,400 mm (L x W x H)
  • For installation for an on-site backflow loop in DN 50
  • With heated cabinet and thermostat, 230 V, 50 Hz
  • Back-up fuse on site: 1-pin B16A
  • With mounting plate and safety lock
  • Weight: 13.8 kg

Downloads

(Video) TOILET FILLS TOO SLOW!!...QUICK AND EASY FIX!

Add to wallet

Item no.
0178.62.35

Outdoor cabinet for local pressure pipes an controller

Suitable for
  • Muli-Max
  • Powerlift–P
  • LipuLift-P-DA/P-DAP
Description
  • Dimension: 2000 x 806 x 335 mm (H x W x D)
  • With reserve space for installation of an on-site backflow loop according to DIN 12056-4 and 1986-100
  • DN 50 – DN 150
  • With mounting plate incl. base
  • With lamp
  • With CEE32 and work socket with earth contact
  • With heating and thermostat
  • With security lock
  • Weight: 76 kg

Downloads

Add to wallet

Item no.
0178.64.16

Outdoor cabinet for local pressure pipes an controller

Suitable for
  • Muli-Max
  • Powerlift–P
  • LipuLift-P-B/P-D
Description
  • Dimension: 2000 x 806 x 335 mm (H x W x D)
  • With reserve space for installation of an on-site backflow loop according to DIN 12056-4 and 1986-100
  • DN 50 – DN 150
  • With mounting plate incl. base
  • With lamp
  • With CEE16 and work socket with earth contact
  • With heating and thermostat
  • With security lock
  • Weight: 76 kg

Downloads

Add to wallet

Item no.
0178.64.42

Open air cupboard

Suitable for
  • GRP outdoor cabinet for on-site pressure line
    • DN 80
    • DN 100
    • DN 125
    • DN 150
,
  • LipuLift-P Serie
Description
  • With reserve space for installation of an on-site backflow loop according to DIN 12056-4 and 1986-100
  • With mounting plate incl. base
  • With heating and thermostat
  • With CEE32 and work socket with earth contact
  • Dimension: 2000 x 806 x 335 mm (H x W x D)
  • Weight: 100 kg

Downloads

Add to wallet

Item no.
0178.64.06

Pressure pick-up

Suitable for
  • Control ACO Multi-Control Mono/Duo
  • LipuLift-P/LipuLift-PF
  • Muli-Flex
Description
  • 4–20 mA
  • For secure switching cable lengths > 12 m
  • 0–200 mbar
  • With cable for installation: 20 m
  • Weight: 2 kg

Downloads

Add to wallet

Item no.
0178.63.88

Pressure pick-up

Suitable for
  • Control ACO Multi-Control Mono/Duo
  • LipuLift-P/LipuLift-PF
  • Muli-Flex
Description
  • 4–20 mA
  • For secure switching cable lengths > 12 m
  • 0–200 mbar
  • Cable for installation: 40 m
  • Weight: 3.4 kg

Downloads

Add to wallet

Item no.
0178.63.87

Safety barrier

Suitable for
  • Pressure pick-off
  • Float switch with ATEX-certificate
Description
  • To separate Ex-risk and secure areas
  • Incl. housing
  • Weight: 0.5 kg

Downloads

Add to wallet

Item no.
0178.63.89

Guide strap

Suitable for
  • Top section
    • 0178.08.35
Description
  • Quantity required
    • 1 pce for Muli-Max Mono
    • 2 pces for Muli-Max Duo
    • 2 pces for LipuLift-P
  • Weight: 1.6 kg
(Video) How To Install a Sub Panel Start to Finish!

Downloads

Add to wallet

Item no.
0178.08.79

Guide strap

Suitable for
  • Top section
    • 0178.08.36
Description
  • Quantity required
    • 1 pce for Muli-Max Mono
    • 2 pces for Muli-Max Duo
  • Weight: 2 kg

Downloads

Add to wallet

Item no.
0178.08.80

Flushing connection

Suitable for
  • Muli-Max
  • Powerlift–P
  • Muli-Flex
Description
  • Total height: 430 mm
  • Weight: 2 kg

Downloads

Add to wallet

Item no.
0178.05.22

Vacuum relief valve

Suitable for
  • Muli-Max
  • Powerlift–P
  • Powerlift installation kit
Description
  • Only possible in combination with Flushing connection
  • Weight: 1.5 kg

Downloads

Add to wallet

Item no.
0178.09.31

Compression fitting 63 x 63 mm

Suitable for
  • Powerlift installation kit DN 50
  • Powerlift–P
  • LipuLift-P
Description
  • Material: PP
  • Pressure level: PN16
  • For extension of the pressure line pipe Ø63 mm
  • Weight: 0.6 kg

Downloads

Add to wallet

Item no.
0150.38.38

Compression fitting 63 x 75 mm

Suitable for
  • Powerlift installation kit DN 50
  • Powerlift–P
  • LipuLift-P
Description
  • Material: PP
  • Pressure level: PN16
  • For extending the pressure line diameter from Ø63 mm to Ø75 mm
  • Weight: 0.8 kg

Downloads

Add to wallet

Item no.
0178.13.09

Compression fitting 63 x 90 mm

Suitable for
  • Powerlift installation kit DN 50
  • Powerlift–P
  • LipuLift-P
Description
  • Material: PP
  • Pressure level: PN16
  • For extending the pressure line diameter from Ø63 mm to Ø90 mm
  • Weight: 0.7 kg

Downloads

Add to wallet

(Video) How To Wire DVC 4 Ohm Subwoofer

Item no.
0178.13.10

Videos

1. How to stop screwing yourself over | Mel Robbins | TEDxSF
(TEDx Talks)
2. 2023 NCAA DIII indoor track & field championship: Day one full replay
(NCAA Championships)
3. Primary Secondary Piping
(FIA Inc)
4. HOW IMPORTANT SUBSONIC SETTING IS ON YOUR AMPLIFIER?
(Jacob Viral2)
5. Classic Vanilla WoW Priest Deep-Dive with Lezonta | Classic WoW Priest Guide
(Tips Out)
6. 30 Cool Vehicle Inventions Changing how we Travel
(MINDS EYE DESIGN)
Top Articles
Latest Posts
Article information

Author: Tyson Zemlak

Last Updated: 21/05/2023

Views: 5431

Rating: 4.2 / 5 (63 voted)

Reviews: 86% of readers found this page helpful

Author information

Name: Tyson Zemlak

Birthday: 1992-03-17

Address: Apt. 662 96191 Quigley Dam, Kubview, MA 42013

Phone: +441678032891

Job: Community-Services Orchestrator

Hobby: Coffee roasting, Calligraphy, Metalworking, Fashion, Vehicle restoration, Shopping, Photography

Introduction: My name is Tyson Zemlak, I am a excited, light, sparkling, super, open, fair, magnificent person who loves writing and wants to share my knowledge and understanding with you.