Specifications: Fluke Ti105 a3001 FC iFlex® Kit

Detailed Specifications
IR resolution (FPA size)160 x 120 FPA Uncooled Microbolometer
Spectral band7.5 µm to 14 µm (long wave)
Capture or refresh rate30 Hz version
NETD (thermal sensitivity)≤ 0.10°C at 30°C target temp (100 mK)
FOV (field of view)22.5° H x 31° V
IFOV (spatial resolution)3.39 mRad
Temperature measurement range (not calibrated below -10°C)-20°C to + 250°C (-4°F to 482°F)
Temperature measurement accuracy±2°C or 2% (at 25°C nominal, whichever is greater)
Focus mechanismFocus-free 1.2 m (4 ft) and beyond
IR Fusion® technologyPIP (1.2 m (4 ft) to 4.6 m (15 ft)), full IR, full visible
Fluke Connect compatibilityYes (where available)
Color alarms-
Standard palettesBlue-red, ironbow, grayscale and amber
Ultra Contrast™ palettes-
Hot/cold markers-
User definable spot markersIn SmartView® only
CenterpointYes
Centerbox (MIN/AVG/MAX)-
Level and span controlManual and auto
Minimum span in auto mode5°C
Minimum span in manual mode2.5°C
Minimum IR focus distance122 cm (48 in)
Weight0.726 kg (1.6 lb)
Size28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display3.5 inch diagonal (portrait format)
Visible camera2 megapixel industrial-grade
Minimum parallax~122 cm (48 in)
IR-PhotoNotes™ annotation system-
Laser pointerYes
TorchYes
Electronic (cardinal) compass-
Emissivity correctionYes
Transmission correction-
Background (reflected) compensationYes
Voice annotation (audio)-
Multi-mode video output-
Multi-mode video recording (standard AVI with MPEG encoding)-
Multi-mode video recording (radiometric .IS3)-
Memory reviewThumbnail review
Battery (field-replaceable, rechargeable)One
Battery life4+ hours (each)*
External battery charging baseOptional (accessory)
Charging power supplyYes
Drop test2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529)IP 54
Recommended calibration cycleTwo-years
Multifunction card reader-
Memory storage2 GB SD memory card
Direct download capabilityMini USB download direct to PC
Operating temperature range-10°C to +50°C (14°F to 122°F)
Storage temperature range-20°C to +50°C (-4°F to 122°F)
Operating humidityOperating and storage 10% to 95%, non-condensing
Vibration and shock2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standardsIEC 61010-1: Cat None, Pollution Degree 2
C TickIEC/EN 61326-1
EMI, RFI, EMCEN61326-1; FCC Part 5
User manualsCzech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty periodTwo-years
Extended warranty and service plansYes
*Assumes 50% brightness of LCD

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ± ([% of Reading ] + [ Number of least significant digits ]).

Fluke 3000 FC Series Wireless Multimeter

AC Voltage
Range¹ / resolution600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2 3 445 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mVRange / resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
ΩRange / resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC
(45 Hz to 1 kHz)
Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mA
Accuracy1.5% + 3
mA DC2Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mA
Accuracy0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy10.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Fluke Ti105 a3001 FC iFlex® Kit (1)Overload protection1100 Vrms
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Fluke Ti105 a3001 FC iFlex® Kit (2)Overload protection1100 Vrms
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Fluke Ti105 a3001 FC iFlex® Kit (3)Overload protection1100 Vrms
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Fluke Ti105 a3001 FC iFlex® Kit (4)Overload protection1100 Vrms
Input impedance (nominal)< 2.7 VDC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
< 0.7 VDC
< 0.9 VDC
Typical short circuit current< 350 mA
Fluke Ti105 a3001 FC iFlex® Kit (5)Overload protection1100 Vrms
Input impedance (nominal)< 2.7 VDC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
2.000 VDC
Typical short circuit current< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions±12 counts for changes > 350 mS in duration.
AC functions±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 VDC or AC rms
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20m
Obstructed, sheetrock wallUp to 6.5m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

Fluke a3001 FC Wireless iFlex AC Current Module

Specifications
Range0.5 A to 2500 A AC
Resolution0.1 A
Accuracy3% ± 5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity90% at 35°C
75% at 40°C
45% at 50°C
AltitudeOperating2,000 m
Storage12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Jaw opening25.4 cm (10 in) coil
Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

Models: Fluke Ti105 a3001 FC iFlex® Kit

FLK-Ti105 30HZ/FCA KIT

Fluke Ti105 a3001 FC iFlex® Kit

Includes:

Fluke 105 Infrared Camera

  • AC power adapter
  • Lithium ion smart battery (1)
  • USB cable
  • SD memory card
  • Fluke Connect™ WiFi SD Card
  • Hard carrying case
  • Soft transport bag
  • Adjustable hand strap (left- or right-handed use)
  • Printed users' manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD
  • SmartView® software
  • Warranty registration card

Fluke 3000 FC Wireless Digital Multimeter with three (3) AA batteries (installed)

  • One (1) a3001 FC Module with two (2) AA batteries (installed)
  • One (1) iFlex 10" coil
  • One (1) magnet/strap
  • TL175 Test Leads (1 pair)
  • AC175 Alligator Clips (1 pair)
  • C3003 3-compartment soft case
  • Information pack

FLK-Ti105 9HZ/FCA

Fluke Ti105 a3001 FC iFlex® Kit

Includes:

Fluke 105 Infrared Camera

  • AC power adapter
  • Lithium ion smart battery (1)
  • USB cable
  • SD memory card
  • Fluke Connect™ WiFi SD Card
  • Hard carrying case
  • Soft transport bag
  • Adjustable hand strap (left- or right-handed use)
  • Printed users' manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD
  • SmartView® software
  • Warranty registration card

Fluke 3000 FC Wireless Digital Multimeter with three (3) AA batteries (installed)

  • One (1) a3001 FC Module with two (2) AA batteries (installed)
  • One (1) iFlex 10" coil
  • One (1) magnet/strap
  • TL175 Test Leads (1 pair)
  • AC175 Alligator Clips (1 pair)
  • C3003 3-compartment soft case
  • Information pack

Manuals + resources: Fluke Ti105 a3001 FC iFlex® Kit

Manuals (2)

  • Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 | Users manual
  • Fluke Connect Wi-Fi to Thermal Imager | Quick reference guide

Other (1)

  • Basic Troubleshooting for Fluke Ti125-Ti110-Ti105-Ti100-Ti95-Ti90-TiR125-TiR110-TiR105 Operation and Performance Issues

Brochure (1)

  • Fluke Connect Country Guide

Data sheets (1)

  • Fluke Ti105 a3001 FC iFlex® Kit | Data sheets

Related links (1)

  • FOV Calculator

Videos (17)

Register products

  • Register product
Top Articles
Latest Posts
Article information

Author: Amb. Frankie Simonis

Last Updated: 22/04/2023

Views: 6628

Rating: 4.6 / 5 (76 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Amb. Frankie Simonis

Birthday: 1998-02-19

Address: 64841 Delmar Isle, North Wiley, OR 74073

Phone: +17844167847676

Job: Forward IT Agent

Hobby: LARPing, Kitesurfing, Sewing, Digital arts, Sand art, Gardening, Dance

Introduction: My name is Amb. Frankie Simonis, I am a hilarious, enchanting, energetic, cooperative, innocent, cute, joyous person who loves writing and wants to share my knowledge and understanding with you.